Skip to main content
OPEN NOW
0s

0% of today's working hours elapsed

Office Hours (IST)

Mon – Fri9:00 AM – 6:00 PM
Saturday9:00 AM – 3:00 PM
SundayClosed
Track Repair →
1 Products

A & D COMPANY Repair Services India

A & D Company (AND) is a Japan-based leader in precision weighing scales, balances, and measurement instruments serving pharmaceutical, chemical, food processing, and laboratory sectors worldwide. Their instruments are critical for quality control and compliance in Indian manufacturing. AND equipment is trusted across pharma plants in Ahmedabad, chemical facilities in GIDC, and food producers nationwide for accuracy and reliability.

A & D Company (AND) is a Japan-based leader in precision weighing scales, balances, and measurement instruments serving pharmaceutical, chemical, food processing, and laboratory sectors worldwide. Their instruments are critical for quality control and compliance in Indian manufacturing. AND equipment is trusted across pharma plants in Ahmedabad, chemical facilities in GIDC, and food producers nationwide for accuracy and reliability.

Synchronics specializes in repairing A & D Company analytical balances, industrial scales, moisture analyzers, and density measurement systems used across Indian pharma and manufacturing. Our 180+ engineers have logged 28+ years repairing AND load cells, display modules, connectivity boards, and sensor interfaces. We diagnose calibration drift, weighing errors, and communication faults that disrupt production compliance and batch certification in regulated environments.

Expert AND scale and balance repair for pharma, chemical, and food manufacturing across India.

1
Products in Catalog
1+
Product Categories
6 Mo
Repair Warranty
32+
Years Experience

A & D COMPANY Equipment We Repair — By Category

Repair Expertise

A & D COMPANY Product Lines We Repair

Our engineers are trained on the full A & D COMPANY product range. Below are the major product families we service.

GF Series Analytical Balances

High-precision balances (0.01mg to 220g capacity) for pharmaceutical, chemical, and laboratory use. Common faults include load cell drift, drift in display readings after power cycles, and connectivity loss to production systems.

GF-200GF-300GF-400GF-600

HR Series Industrial Scales

Robust platform and bench scales (5kg to 150kg) for food, chemical, and bulk material weighing. Repair issues include sensor calibration loss, platform tilt errors, and RS-232/USB communication failures.

HR-150HR-200HR-300HR-600

FX Series Moisture Analyzers

Rapid moisture content testers for pharma, food, and chemical QC. Faults typically involve heating element failure, sensor deterioration, and display panel malfunction causing incorrect moisture percentage readings.

FX-200FX-300iFX-500i

PR Series Precision Scales

Laboratory and checkweighing scales with compact footprint. Common repairs include load cell replacement, software calibration reset, and connectivity module repair for data export to QMS.

PR-200PR-500PR-1000

Apollo Series Multi-Function Scales

Advanced scales with built-in statistics, percentage weighing, and networking. Repair work involves touchscreen failure, EEPROM calibration data corruption, and Ethernet module replacement.

Apollo GX-100Apollo GX-200Apollo GX-800
Why Us

Why Choose Synchronics for A & D COMPANY Repairs?

🔬

PCB-Level Expertise

We repair down to the component level — not just swap boards. Our engineers identify root causes, replace failed IGBTs, capacitors, processors, and gate drivers on A & D COMPANY equipment.

Fast Turnaround

Standard 7–10 working days. Express 3–5 days available for critical breakdowns. Emergency same-day/next-day service for unplanned downtime.

🛡️

6-Month Warranty

Every repaired unit ships with a 6-month comprehensive warranty on parts and labour. Our repair success rate is over 94% across all brands.

📦

All-India Service

Couriered repairs accepted from any city in India. Doorstep pickup available in Vadodara, Mumbai, Pune, Ahmedabad, Surat, Chennai, and more.

Diagnosis

Common A & D COMPANY Equipment Faults We Fix

Based on 30+ years of repair data, these are the most frequent failure modes we see in A & D COMPANY equipment arriving at our workshop.

  • Load cell output drift and zero point instability — AND load cells degrade under humidity, thermal stress, or vibration in factory environments. Moisture ingress into sensor connectors and mechanical stress on cantilever beams cause output voltage drift, leading to out-of-tolerance weighing across batch runs.
  • Display panel freezes or shows corrupt weight readings — AND display modules accumulate dust and electrolytic capacitor failure in high-temperature pharma and chemical production areas. Firmware corruption from power surges or EMI from nearby machinery causes erratic digit display and locked-up interfaces.
  • RS-232 and USB communication port failure — AND connectivity modules suffer from loose headers, oxidized solder joints, and electrostatic damage from ESD events during maintenance in static-prone facilities. Port voltage regulation failures cause intermittent data transmission to QMS and batch record systems.
  • Heating element burnout in moisture analyzers — FX Series heating elements degrade after 5000+ measurement cycles or when overheated by continuous operation without proper cooldown intervals. Element resistance increases, causing slow heating, inaccurate moisture readings, and error messages.
  • EEPROM calibration data corruption and loss of zero offset — AND scale memory becomes corrupted by unexpected power loss, firmware updates interrupted by voltage sag, or bit-flip errors in EEPROM during high-humidity storage or transport. Scales lose calibration constants, requiring full recalibration per batch.
  • Weighing pan tilt and platform alignment errors — HR and PR Series scales develop platform tilt from vibration, floor settling, or impact during relocation. Mechanical misalignment causes load cell strain, zero drift, and out-of-spec weight readings across the full measurement range.
Process

How We Repair Your A & D COMPANY Unit

📥
Step 1

Receive & Log

Your unit is logged into our tracking system with a unique job number. You receive WhatsApp / email updates at every stage.

🔬
Step 2

Fault Diagnosis

Board-level diagnosis using oscilloscopes, LCR meters, and thermal cameras. Root cause identified before any repair begins.

🔧
Step 3

Component Repair

Faulty ICs, capacitors, MOSFETs, IGBTs, and gate drivers replaced with genuine or equivalent-spec components.

Step 4

Full-Load Test

Unit tested under rated load with original or equivalent motor. All parameters verified. 6-month warranty issued.

Sectors

Industries Using A & D COMPANY Equipment

We serve plant maintenance teams across all major industries where A & D COMPANY automation is deployed.

Pharmaceuticals - capsule, tablet, and powder batch weighing for API and formulation QCFine Chemicals - precise ingredient measurement for specialized synthesis and compound productionFood and Beverages - ingredient control, package weight verification, and moisture testing for snacks and dairyContract Manufacturing - job work facilities requiring flexible, certified weighing for diverse customer batchesNutraceuticals - vitamin, mineral, and herbal supplement dosing and packaging weight controlSpice and Seasoning - ingredient proportioning and moisture analysis for export-grade spice blendsLaboratory and Research - analytical work in university and government testing facilities across India
FAQ

Frequently Asked Questions — A & D COMPANY Repairs

Do you repair A & D Company equipment anywhere in India?+

Yes. Synchronics repairs the full A & D Company product range — analytical balances, industrial scales, moisture analyzers, and precision weighing systems. We offer PAN India door pickup from Mumbai, Delhi, Pune, Chennai, Hyderabad, Ahmedabad, Jaipur, Kolkata, and all other cities. Same facility in Vadodara, Gujarat for centralized diagnostics and rapid turnaround.

My AND GF Series balance shows 'CAL ERROR' and drifts after power-up. How long to repair?+

CAL ERROR in GF Series indicates load cell output drift or corrupted calibration constants in EEPROM. Synchronics diagnoses the root cause in 1-2 hours (load cell vs. electronics), performs repair or replacement, and recalibrates with certified weights. Typical TAT is 3-5 working days including courier time. We'll contact you with a cost estimate before proceeding.

We need AND scales for pharmaceutical batch certification. Are your repairs validated for FDA/ICH compliance?+

Yes. Synchronics restores AND scales to OEM specification and ISO 9001 standards. We provide calibration certificates traceable to national standards and detailed repair reports documenting parts replaced and test results. Many pharma customers use our repaired scales for regulated batch release. Consult our quality team for compliance documentation tailored to your QMS.

What warranty do you offer on AND scale repairs?+

Synchronics provides 12 months parts and labor warranty on all A & D Company repairs. Load cells, display modules, and logic boards are covered. Warranty excludes wear items (feet, cables) and damage from external impact or liquid spill. We recommend annual preventive maintenance to catch drift and aging components early.

Can you upgrade old A & D Company scales with Ethernet and cloud connectivity for Industry 4.0?+

Synchronics can retrofit older AND scales with modern USB and Ethernet modules, and integrate them with cloud-based production tracking systems used by Indian manufacturers. We assess your scale model and plant network infrastructure, then recommend compatible connectivity solutions. Contact our engineering team for a custom upgrade proposal.

How do I send my A & D COMPANY unit for repair?+

Pack the unit securely and courier it to our Vadodara workshop. Include a note with the fault description and your contact details. We will log it into our system and WhatsApp you a job number within 24 hours of receipt. Doorstep pickup is available in Vadodara, Ahmedabad, Surat, Mumbai, and Pune.

What is the cost of repairing a A & D COMPANY drive or PLC?+

Repair cost depends on the model and the fault. We offer a free diagnosis — once we identify the fault, we provide a fixed quotation before proceeding. Typical repairs cost 20–40% of the new unit price. We will never repair without your approval.

What warranty do you provide on A & D COMPANY repairs?+

All repaired units carry a 6-month comprehensive warranty covering the same fault and related issues. If the fault recurs within the warranty period, we repair it free of cost.

Do you provide a no-fix, no-fee guarantee?+

Yes. If we cannot repair your A & D COMPANY unit after diagnosis, you pay only the diagnosis fee (₹500–₹1,500 depending on the product). The unit is returned to you at no additional charge.

A & D COMPANY Repair Catalog

Showing 11 of 1 A & D COMPANY products

Other Brands We Repair in the Same Categories

32+
Years in Business
80,000+
Units Repaired
150+
Workstations
4.8★
682 Reviews
Trusted Since 1994 · ISO Certified · 32+ Years

Get Your Equipment
Back in Action — Fast

Send us your faulty industrial electronics. Our engineers will diagnose it and provide a detailed quote within 24 hours — with no obligation to proceed.

Free Evaluation

No obligation

48hr Turnaround

Fastest in India

🛡

6-Month Warranty

Every repair

No Fix, No Charge

Zero risk policy

📦

Pan-India Pickup

Doorstep service