Power Electronics

Power Supply Repair

Industrial SMPS, UPS, servo stabiliser, and panel power supply repair — all ratings, component-level, load tested before dispatch.

8,000+
Power Supplies Repaired
100%
Full Load Tested
24hr
Express Service Available
50W–500kVA
Rating Range Covered
Scroll

A failed power supply can cascade into damage across your entire production line — we fix the root cause and load test every repair at full rated current.

8,000+
Power Supplies Repaired
100%
Full Load Tested
All
Topologies Covered
95%
First-Time Fix Rate
50W–500kVA
Rating Range
6 Months
Repair Warranty
Overview

Industrial power supplies are the silent backbone of every automated facility — when an SMPS fails, it can trigger a cascade of faults across PLCs, drives, sensors, and HMIs connected downstream. Synchronics repairs industrial power supplies at the component level — MOSFETs, IGBTs, PWM controller ICs, isolation transformers, rectifier bridges, and output filter capacitors — across all topologies including flyback, forward converter, half-bridge, full-bridge, and LLC resonant designs. Every single repair is load tested at full rated current with efficiency and ripple measurements before dispatch.

SMPS Repair (All Topologies)
Component-level repair of switch-mode power supplies — flyback, forward, half-bridge, full-bridge, and LLC resonant converters. PWM controller IC replacement, transformer rewind, and feedback loop recalibration.
UPS Main Board & Charger
Online and line-interactive UPS repair — inverter board, charger section, battery management IC, transfer switch relay, and DSP controller board repair. Battery health assessment included.
Servo Stabiliser Repair
Servo voltage stabiliser motor drive card, buck-boost transformer tap changer, voltage sensing circuit, and motor control board repair. Calibrated for precise voltage regulation.
Panel PSU / DIN Rail PSU
DIN rail mount and panel power supply repair — Siemens SITOP, Phoenix Contact QUINT, Puls, and Weidmuller units. Output voltage and current limit recalibration after repair.
MOSFET / IGBT Replacement
Power semiconductor replacement with exact-spec or upgraded devices. Gate driver circuit repair, snubber network recalculation, and thermal compound reapplication for optimal heat dissipation.
Full Load Testing
Every repaired power supply is tested at rated output current using our programmable electronic load banks. Output voltage regulation, ripple voltage, efficiency, thermal rise, and protection trip points are all verified.

Diagnosis Guide

Common Power Supply Problems We Fix

Experiencing any of these symptoms? Our engineers have diagnosed and repaired thousands of these faults.

critical

SMPS No Output

Symptom

Power supply is dead — no output voltage, no LED indication, no fan spin. Connected equipment is completely offline.

Common Cause

Input fuse blown due to shorted MOSFET/IGBT, failed bridge rectifier, or dried-out input filter capacitors causing startup circuit failure

critical

UPS Not Charging / Not Switching

Symptom

UPS shows charging fault, batteries not charging, or UPS fails to switch to battery during power cut — load drops instantly

Common Cause

Charger thyristor/MOSFET failure, battery management IC fault, relay contact welding, or transfer switch driver circuit failure

high

Servo Stabiliser Motor Failure

Symptom

Output voltage not regulating, motor buzzing but not correcting, or stabiliser trips repeatedly on overload

Common Cause

Servo motor brush wear or bearing seizure, motor drive TRIAC failure, voltage sensing resistor drift, or control card relay fault

high

Panel PSU Voltage Drift

Symptom

Output voltage slowly drifting from 24V to 22V or 26V, causing intermittent PLC and sensor faults downstream

Common Cause

Feedback resistor value drift due to thermal ageing, optocoupler CTR degradation, or TL431 reference IC failure

critical

MOSFET / IGBT Blown

Symptom

Loud pop at startup, burning smell, input fuse blown immediately, or output pulsing on and off (hiccup mode)

Common Cause

Switching transistor avalanche breakdown from voltage spike, gate driver IC failure causing shoot-through, or inadequate snubber network

moderate

Electrolytic Capacitor Failure

Symptom

Output ripple increased, audible buzzing from transformer, intermittent shutdowns under load, or visibly bulged/leaking capacitors

Common Cause

Capacitor ESR increase from thermal ageing (especially near heat sinks), exceeding rated temperature or ripple current, or poor ventilation

How It Works

Our Power Supply Repair Process

A systematic, schematic-driven repair process — from receipt to dispatch.

01
STEP 01

Receive & Log

Power supply received with nameplate details, fault history, and application context logged. Unit is photographed for reference.

We record input voltage, output rating, and the downstream equipment it powers to understand criticality.
02
STEP 02

Visual & Smell Test

Physical inspection for burnt components, bulged capacitors, discoloured PCB areas, cracked solder joints, and signs of liquid ingress or overheating.

Many power supply faults are visually identifiable — burned MOSFETs, swollen caps, or arcing marks on the PCB.
03
STEP 03

Input / Output Measurement

Input section tested — fuse continuity, bridge rectifier diode check, bulk capacitor voltage. Output section tested — DC output under no-load and light-load conditions.

We use isolation transformer and variac for safe power-up to prevent further damage to the unit.
04
STEP 04

Topology Analysis & Signal Tracing

Power supply topology identified (flyback, forward, half-bridge, full-bridge, LLC) and critical signals traced — PWM output, gate drive waveforms, feedback loop, and current sense signals.

Oscilloscope used to verify PWM frequency, duty cycle, dead time, and feedback loop stability.
05
STEP 05

Component-Level Repair

Faulty MOSFETs, IGBTs, diodes, capacitors, PWM controller ICs, optocouplers, and gate driver ICs replaced with original-spec or upgraded components.

All replacements are from authorised distributors. Thermal compound and heat sink mounting verified.
06
STEP 06

Full Load Test & Dispatch

Repaired unit tested at full rated output current using programmable electronic load bank. Voltage regulation, ripple, efficiency, and thermal rise measured and documented.

Test report with load curves dispatched with the unit. 6-month warranty on all component-level repairs.

Thorough Inspection

Power Supply Inspection Checklist

Every unit goes through a comprehensive inspection checklist before and after repair.

Input Filter & Rectifier

Input fuse and MOV surge protector continuity
Bridge rectifier diode forward/reverse check
Bulk filter capacitor ESR and capacitance
Common-mode and differential-mode choke integrity
Inrush current limiter (NTC or relay) functionality

Switching MOSFETs / IGBTs

Drain-source / collector-emitter resistance
Gate threshold voltage test
Gate driver IC output waveform and amplitude
Snubber network component values
Thermal compound condition and heat sink mounting torque

PWM Controller IC

Supply voltage (Vcc) to controller IC
Oscillator frequency and ramp waveform
Feedback pin voltage and optocoupler response
Soft-start capacitor charging profile
Overcurrent and overvoltage protection thresholds

Output Filter & Rectification

Output rectifier diode / synchronous FET forward drop
Output inductor winding resistance and core integrity
Output capacitor ESR and ripple current rating
Output voltage accuracy at no-load and full-load
Output ripple voltage measurement (oscilloscope)

Feedback Loop & Regulation

TL431 / shunt regulator reference voltage accuracy
Optocoupler CTR (current transfer ratio) measurement
Voltage divider resistor values and tolerance
Regulation accuracy from 10% to 100% load
Transient load step response (voltage dip/overshoot)

Protection Circuits

Overvoltage protection (OVP) trip point
Overcurrent protection (OCP) trip point
Short-circuit protection and recovery behaviour
Over-temperature protection (thermal switch / NTC)
Under-voltage lockout (UVLO) threshold

The Synchronics Advantage

Why Choose Us for Power Supply Repair

All Topologies — Flyback to Full-Bridge

Our power electronics team is trained on every SMPS topology in use today — from simple flyback converters in 50W panel PSUs to complex full-bridge and LLC resonant converters in multi-kilowatt UPS systems. We understand the magnetics, control loops, and failure modes unique to each topology.

Load Tested at Full Rated Current

We do not dispatch any repaired power supply based on a no-load voltage check. Every unit is connected to our programmable electronic load bank and tested at 100% rated current for a sustained duration. We measure voltage regulation, ripple, efficiency, and thermal rise — and include the test report with your unit.

UPS Battery System Expertise

Beyond board-level UPS repair, we assess battery health, charger circuit calibration, and transfer switch timing. For online UPS systems, we verify seamless zero-transfer-time switchover. For large UPS installations, we provide on-site commissioning support after repair.

Troubleshooting

Common Power Supply Fault Symptoms We Repair

Seeing one of these error codes? We diagnose and repair the root cause.

No Output
Meaning

Power supply completely dead — no output voltage, no standby LED

Possible Cause

Blown input fuse from shorted MOSFET, failed startup resistor, or open primary winding on transformer

Low Voltage
Meaning

Output voltage below rated value (e.g. 24V supply reading 18-20V)

Possible Cause

Feedback optocoupler CTR degradation, TL431 reference drift, or output capacitor ESR increase causing voltage drop under load

Overvoltage
Meaning

Output voltage above rated value — risk of damaging connected equipment

Possible Cause

Feedback loop open (broken optocoupler), voltage divider resistor gone open, or shorted output rectifier in multi-output supply

Overcurrent Shutdown
Meaning

Supply starts briefly then shuts down, or enters hiccup/retry mode

Possible Cause

Output short or overload, current sense resistor drift, PWM controller OCP threshold shifted, or secondary rectifier leaking

Fan Alarm / Overtemp
Meaning

Cooling fan not running, supply overheating and tripping on thermal protection

Possible Cause

Fan bearing seizure, fan driver transistor failure, blocked air filter, or thermal switch/NTC open circuit

Battery Fault (UPS)
Meaning

UPS reports battery not charging, battery low, or fails to support load on mains failure

Possible Cause

Charger thyristor/MOSFET failure, battery management IC fault, battery connector corrosion, or end-of-life battery cells

Power supply faults manifest as symptoms rather than alphanumeric fault codes. We diagnose based on the behaviour observed and the topology of your specific unit. Send us a photo of the nameplate and a description of the fault for a free repair estimate.

Industries Served

Where Power Supplys Are Used

Factory Automation

24V DC panel power supplies for PLCs, sensors, solenoid valves, and field instruments. SITOP, QUINT, and PULS DIN rail PSU repair across manufacturing plants.

IT Infrastructure & Data Centres

Rack-mount UPS systems, server power supplies, and PDU repair. Online double-conversion UPS main board repair and battery management for Emerson, APC, and Schneider systems.

Healthcare & Medical Equipment

Medical-grade SMPS repair for diagnostic equipment, patient monitors, and imaging systems. Compliance with safety isolation requirements and leakage current standards.

Telecom & Broadcasting

-48V DC rectifier module repair, telecom power plants, and DC-DC converter repair for base stations and exchange equipment. N+1 redundancy system commissioning.

Process Control & Petrochemical

Redundant 24V power supply repair for DCS and SCADA systems. Intrinsically safe power supply repair for hazardous area applications in refineries and chemical plants.

Textile & Packaging Machinery

Servo stabiliser and panel PSU repair for looms, knitting machines, and packaging lines where voltage stability is critical for consistent product quality.

FAQ

Frequently Asked Questions

Yes — without exception. Every repaired power supply is connected to our programmable electronic load bank and tested at 100% rated output current for a sustained period. We measure and document output voltage regulation, ripple voltage, efficiency, and thermal rise. The load test report is dispatched with your unit as proof of performance.

Yes. We maintain a database of pin-compatible and functionally equivalent PWM controller ICs. If the original IC (e.g. UC3842, TOP-Switch, or proprietary ASIC) is obsolete, we identify a suitable replacement and modify the peripheral circuit values if needed to match the original switching parameters. This is one of our core competencies in power supply repair.

For large-frame UPS systems (above 10kVA) where shipping is impractical, we offer on-site diagnosis and board-level repair at your facility. Our engineers carry portable test equipment and common replacement components. For smaller UPS units, we recommend shipping to our Vadodara facility where we have complete test infrastructure including battery load banks.

Electrolytic capacitors fail primarily due to thermal stress — operating near a heat source, poor ventilation, or exceeding rated ripple current. During repair, we replace failed capacitors with higher-temperature-rated (105 deg C) and higher-ripple-rated units where possible. We also check heat sink mounting, fan operation, and airflow paths to address the root cause of premature capacitor ageing.

Industrial Power Supply Repair Specialists — All Brands, All Ratings

Synchronics Electronics Pvt. Ltd. is a leading industrial power supply repair company in India, operating from our well-equipped facility in Vadodara, Gujarat. We repair SMPS units, online and line-interactive UPS systems, servo voltage stabilisers, DIN rail panel power supplies, and custom power conversion equipment across all ratings from 50W panel PSUs to 500kVA UPS installations. Our power electronics team has repaired over 8,000 units for factories, data centres, hospitals, telecom facilities, and process plants across India.

What makes Synchronics the preferred choice for power supply repair is our commitment to full load testing. While many repair shops check output voltage at no-load and call it done, we connect every repaired unit to a programmable electronic load bank and run it at full rated current — measuring voltage regulation, output ripple, conversion efficiency, and thermal behaviour. This rigorous testing, combined with our use of genuine replacement components from authorised distributors and a 6-month warranty, ensures that your repaired power supply will perform reliably in the demanding conditions of an industrial environment.

Trusted Since 1994 · ISO Certified · 32+ Years

Get Your Equipment
Back in Action — Fast

Send us your faulty industrial electronics. Our engineers will diagnose it and provide a detailed quote within 24 hours — with no obligation to proceed.

Free Evaluation

No obligation

48hr Turnaround

Fastest in India

🛡

6-Month Warranty

Every repair

No Fix, No Charge

Zero risk policy

📦

Pan-India Pickup

Doorstep service