Skip to main content
OPEN NOW
0s

0% of today's working hours elapsed

Office Hours (IST)

Mon – Fri9:00 AM – 6:00 PM
Saturday9:00 AM – 3:00 PM
SundayClosed
Track Repair →
HPLC Repair Specialists

HPLC System Repair

Component-Level Repair for Waters, Shimadzu, Agilent, PerkinElmer & Thermo Fisher HPLC — Serving Pharma QC & R&D Labs Across India

1,00,000+
Repairs Completed
98.7%
First-Fix Rate
48 hrs
Turnaround
6 mo
Warranty
Scroll

India's leading HPLC Repair Laboratory — Gujarat, Maharashtra, Hyderabad & beyond

1,00,000+
Repairs Completed
98.7%
First-Fix Rate
48 hrs
Avg Turnaround
32+
Years Experience
6 mo
Warranty
8+
HPLC Brands Serviced
Overview

Synchronics delivers component-level HPLC repair services to pharmaceutical QC laboratories, research institutions, and food testing labs across India. Our trained electronics engineers repair pump heads, seal kits, and piston assemblies, bringing failed pump modules back to full specification without the cost of OEM replacement. We specialise in detector lamp power supply boards for UV, DAD, FLD, RID, and ELSD detectors — recovering signal integrity where others simply replace the entire detector. Autosampler PCBs, including stepper motor controllers and position encoder circuits, are diagnosed using dedicated test fixtures. Degasser module electronics and column oven temperature controllers are repaired at the component level. We serve pharma clusters in Vadodara, Ahmedabad, Ankleshwar, Vapi, Pune, Hyderabad, and Mumbai, offering 48-hour standard turnaround with full audit-trail documentation suited to GMP environments.

Pump Module Repair
Pump head rebuilds, seal and piston assembly replacement, check valve servicing, and proportioning valve electronics repair.
Detector Electronics (UV/DAD/FLD)
Lamp power supply board repair, photodiode array electronics, deuterium lamp replacement, and FLD PMT circuit diagnosis.
Autosampler PCB Repair
Stepper motor driver board repair, position encoder fault diagnosis, needle and syringe actuator circuit repair.
Degasser & Column Oven
Degasser membrane and vacuum pump electronics, column oven heater controller board repair, and thermocouple circuit diagnosis.
System Qualification Support
Post-repair IQ/OQ documentation support, performance qualification test execution, and GMP-compliant service records.
All Major HPLC Brands
Waters Alliance, Shimadzu Prominence, Agilent 1260/1290, PerkinElmer Flexar, Thermo Vanquish, Varian ProStar, and more.

Diagnosis Guide

Common HPLC System Problems We Fix

Experiencing any of these symptoms? Our engineers have diagnosed and repaired thousands of these faults.

critical

No Pressure Build-up

Symptom

Pump runs but no backpressure, mobile phase not delivered

Common Cause

Pump seal failure, piston crack, or check valve blockage

critical

UV Detector Signal Loss

Symptom

Flat baseline, no peaks detected despite sample injection

Common Cause

Deuterium lamp failure or detector board fault

high

Autosampler Injection Error

Symptom

System error on injection, vial not found, needle stuck

Common Cause

Stepper motor failure or position encoder fault

high

System Communication Error

Symptom

Workstation loses connection to HPLC modules

Common Cause

LAN board failure or firmware corruption

How It Works

Our HPLC Repair Process

A systematic, schematic-driven repair process — from receipt to dispatch.

01
STEP 01

Receive & Log

HPLC module is received, photographed, and logged into our ERP system with full component details and reported fault description.

ERP loggedPhotographedFault noted
02
STEP 02

Fluidics & Electronics Diagnosis

Pump pressure test, flow rate calibration check, and electronic diagnosis using oscilloscope and signal analyser against reference schematics.

Pressure testScope analysisSchematic reference
03
STEP 03

Component-Level Repair

Identified failed components replaced — seal kits, piston assemblies, lamp power supply boards, stepper driver ICs — using OEM-grade or equivalent parts.

OEM-grade partsComponent-levelSourced from inventory
04
STEP 04

Performance Verification & Dispatch

Post-repair performance verification with test run and baseline check. GMP documentation issued. Module professionally packed and dispatched within 24 hours.

Performance verifiedGMP docsNext-day dispatch

Thorough Inspection

What We Inspect in Every HPLC Module

Every unit goes through a comprehensive inspection checklist before and after repair.

Pump & Fluidics

Pump seal condition
Piston surface integrity
Check valve seating
Proportioning valve function
Flow accuracy at set rate

Detector System

Lamp power supply voltage
Photodiode array response
Deuterium lamp intensity
Cell window condition
Noise and drift measurement

Electronics & Communication

LAN / serial interface board
Firmware version check
Autosampler controller board
Column oven thermocouple circuit
Degasser vacuum pump drive

The Synchronics Advantage

Why Choose Us for HPLC System Repair

No Fix No Charge

If we cannot repair your HPLC module, you pay nothing. We absorb the diagnosis cost — no risk to your lab budget.

Genuine OEM-Grade Parts

We use genuine or OEM-equivalent replacement parts sourced from authorised suppliers — critical for pharma audit compliance.

Pharma Audit Documentation

Full GMP-compliant service records, component traceability, and post-repair test data provided for your qualification files.

Fast 48hr Turnaround

Most HPLC repairs completed within 48 hours of receipt — minimising downtime in time-sensitive pharmaceutical QC workflows.

Industries Served

Where HPLC Systems Are Used

Pharmaceutical QC Labs

Assay, dissolution, impurity testing on HPLC

Food Testing Labs

Vitamin, additive, and contaminant analysis

Environmental Labs

Pesticide residue and water quality testing

Research Institutes

Method development and analytical research

CRO & CDMO Facilities

Contract analytical testing and product development

Trusted Brands

Brands We Service

Component-level repair for all major manufacturers

FAQ

Frequently Asked Questions

We most frequently repair Waters Alliance (e2695, 2695), Shimadzu Prominence (LC-20A series), Agilent 1260 and 1290 Infinity series, PerkinElmer Flexar, and Thermo Fisher Vanquish and UltiMate 3000 systems. We have dedicated service documentation and test fixtures for these platforms.

Yes. We specialise in older and legacy HPLC systems where OEM support has been discontinued. Our component inventory and schematic library cover platforms going back over 15 years, making us the preferred partner when the manufacturer no longer supports the instrument.

Yes. We stock and supply common HPLC consumable and replacement parts including pump seals, pistons, check valves, deuterium lamps, autosampler syringes, and various electronic sub-assemblies. Contact us with your model number for parts availability.

Our repairs are carried out to OEM specification with full documentation. We provide a post-repair service record including components replaced, test results, and technician sign-off — everything needed to support an OQ re-qualification entry in your instrument logbook.

HPLC Repair Service — Vadodara, Ahmedabad, Mumbai, Pune & Hyderabad

Synchronics operates India's most technically capable HPLC repair facility, serving pharmaceutical manufacturers, contract research organisations, and quality control laboratories across Gujarat, Maharashtra, Telangana, and beyond. Our laboratory electronics team has repaired HPLC systems from all major OEMs — delivering component-level fixes that restore instruments to full specification at a fraction of OEM replacement cost.

India's pharmaceutical hubs — Ankleshwar, Vapi, Hyderabad, Pune, and Mumbai — depend on reliable HPLC instruments for batch release and stability testing. Downtime is directly linked to regulatory risk and revenue loss. Synchronics provides a 48-hour turnaround service with GMP-compliant documentation, ensuring your HPLC is back online with minimal disruption to your analytical schedule.

Trusted Since 1994 · ISO Certified · 32+ Years

Get Your Equipment
Back in Action — Fast

Send us your faulty industrial electronics. Our engineers will diagnose it and provide a detailed quote within 24 hours — with no obligation to proceed.

Free Evaluation

No obligation

48hr Turnaround

Fastest in India

🛡

6-Month Warranty

Every repair

No Fix, No Charge

Zero risk policy

📦

Pan-India Pickup

Doorstep service