Fungilab Repair Services India
Fungilab is a Spanish manufacturer specializing in fermentation vessels, bioreactors, and laboratory bioprocess equipment. Founded in 1981, Fungilab serves pharmaceutical, biotechnology, food & beverage, and research institutions worldwide. Their precision-engineered fermentation systems are critical in Indian pharma manufacturing, contract research organizations (CROs), and academic microbiology labs.
Fungilab is a Spanish manufacturer specializing in fermentation vessels, bioreactors, and laboratory bioprocess equipment. Founded in 1981, Fungilab serves pharmaceutical, biotechnology, food & beverage, and research institutions worldwide. Their precision-engineered fermentation systems are critical in Indian pharma manufacturing, contract research organizations (CROs), and academic microbiology labs.
Synchronics Electronics has extensive experience servicing Fungilab fermentation control systems, temperature regulation electronics, pH/DO probe interfaces, and peristaltic pump controllers. We repair all Fungilab industrial electronics and bioprocess control modules, ensuring minimal downtime for pharmaceutical batch production and research environments across India.
Certified Fungilab bioprocess electronics and fermentation control system repairs across India.
Fungilab Product Lines We Repair
Our engineers are trained on the full Fungilab product range. Below are the major product families we service.
Fungilab Ancell Series
Benchtop and pilot-scale fermentation vessels (2L-50L) with integrated temperature, pH, and dissolved oxygen control.
Fungilab Biostat Bioreactor Line
Modular bioreactor systems (5L-100L+) for mammalian cell culture and microbial fermentation.
Fungilab Control Module (FCM)
Standalone fermentation control electronics managing multiple sensors and actuators.
Fungilab Sensor & Probe Interface
Specialized signal conditioning circuits for Fungilab proprietary pH, DO, and temperature sensors. Frequent failures include amplifier IC burnout, reference voltage instability, and connector oxidation in salt-spray pharmaceutical facilities.
Fungilab Peristaltic Pump Controller
Stepper motor drivers for media feed, acid/base addition, and inoculum pumps in automated fermentation cycles.
Why Choose Synchronics for Fungilab Repairs?
PCB-Level Expertise
We repair down to the component level — not just swap boards. Our engineers identify root causes, replace failed IGBTs, capacitors, processors, and gate drivers on Fungilab equipment.
Fast Turnaround
Standard 7–10 working days. Express 3–5 days available for critical breakdowns. Emergency same-day/next-day service for unplanned downtime.
6-Month Warranty
Every repaired unit ships with a 6-month comprehensive warranty on parts and labour. Our repair success rate is over 94% across all brands.
All-India Service
Couriered repairs accepted from any city in India — Vadodara, Mumbai, Pune, Ahmedabad, Surat, Chennai, and more.
Common Fungilab Equipment Faults We Fix
Based on 30+ years of repair data, these are the most frequent failure modes we see in Fungilab equipment arriving at our workshop.
- ✓Dissolved oxygen (DO) probe signal dropout or stuck reading — Fungilab DO sensors use polarographic cells requiring regular electrolyte renewal. Signal conditioning IC faults, connector corrosion in humid pharmaceutical facilities, or water ingress into probe junction box prevent accurate real-time oxygen monitoring during batch fermentation.
- ✓Temperature controller oscillation or setpoint overshoot — Fungilab fermentation vessels use Pt100 RTD sensors with PID control loops tuned for specific vessel volumes. Sensor drift, water bath heater element fouling, or aged proportional valve solenoids cause temperature swings of 1-2°C during critical batch phases, compromising fermentation kinetics.
- ✓Worn peristaltic pump tubing or clogged check valves also prevent proper media feed delivery.
- ✓Foam sensor false triggers or no detection — Fungilab optical foam detection uses infrared LED and phototransistor sensing foam column height. IR LED aging, photodiode contamination, or signal conditioning amplifier offset drift cause false alarms or missed foam breakthrough, risking broth carryover and cross-contamination.
- ✓Fungilab data logging corruption or WiFi module disconnection — SD card flash memory failure, EEPROM wear-out from frequent batch cycle writes, or WiFi module TCP/IP buffer overflow cause fermentation parameter loss or network dropouts critical for regulatory documentation and SCADA integration in Indian pharma facilities.
How We Repair Your Fungilab Unit
Receive & Log
Your unit is logged into our tracking system with a unique job number. You receive WhatsApp / email updates at every stage.
Fault Diagnosis
Board-level diagnosis using oscilloscopes, LCR meters, and thermal cameras. Root cause identified before any repair begins.
Component Repair
Faulty ICs, capacitors, MOSFETs, IGBTs, and gate drivers replaced with genuine or equivalent-spec components.
Full-Load Test
Unit tested under rated load with original or equivalent motor. All parameters verified. 6-month warranty issued.
Industries Using Fungilab Equipment
We serve plant maintenance teams across all major industries where Fungilab automation is deployed.
Frequently Asked Questions — Fungilab Repairs
Is Synchronics an authorised Fungilab service centre?+
No. Synchronics Electronics Pvt. Ltd. is an independent third-party repair provider. We are not affiliated with, authorised by, sponsored by or endorsed by Fungilab or its group companies, and we are not an official Fungilab service centre, dealer or representative. Brand names and model numbers are used only to identify the equipment we repair. If your equipment is under manufacturer warranty or a service contract, please contact the manufacturer first — third-party repair may affect that cover.
Do you repair Fungilab equipment anywhere in India?+
Yes. Synchronics repairs the full Fungilab product range including Ancell fermentation vessels, Biostat bioreactors, control modules, sensor interfaces, and peristaltic pump controllers.
How long does Fungilab pH probe and DO sensor repair take?+
Standard pH electrode and DO probe refurbishment takes 5-7 business days. Emergency repairs (pH probe only) can be completed in 48 hours. Critical sensor failures affecting batch production are prioritized. We provide loaner Fungilab probe interfaces during repair.
Can Synchronics repair Fungilab fermentation control PCBs and stepper motor drivers?+
Yes. Synchronics specializes in component-level repairs of Fungilab FCM control boards, signal conditioning circuits, peristaltic pump driver boards, and heating element controllers. We maintain a stock of Fungilab-compatible ICs and test all repaired PCBs under load before return.
Does Synchronics offer preventive maintenance contracts for Fungilab bioreactor systems?+
Yes. Synchronics offers quarterly preventive maintenance (PM) contracts for pharmaceutical and research Fungilab installations. We schedule PM between batch cycles to minimize production downtime.
How do I send my Fungilab unit for repair?+
Pack the unit securely and courier it to our Vadodara workshop. Include a note with the fault description and your contact details. We will log it into our system and WhatsApp you a job number within 24 hours of receipt.
What is the cost of repairing a Fungilab drive or PLC?+
Repair cost depends on the model and the fault. We offer a free diagnosis — once we identify the fault, we provide a fixed quotation before proceeding. Typical repairs cost 20–40% of the new unit price. We will never repair without your approval.
What warranty do you provide on Fungilab repairs?+
All repaired units carry a 6-month comprehensive warranty covering the same fault and related issues. If the fault recurs within the warranty period, we repair it free of cost.
Do you provide a no-fix, no-fee guarantee?+
Yes. For standard units, evaluation is free and included in the repair cost — if we cannot repair your Fungilab unit, no repair charge is raised. A physical inspection charge applies only if the unit has already been subjected to a third-party repair attempt, and we tell you before we start.
Fungilab Repair Catalog
No products found for Fungilab
Don't See Your Fungilab Model Listed?
We repair the full range of Fungilab industrial electronics — even if the specific model is not yet in our catalog. Send us the unit details and we'll confirm repairability within 24 hours.
Free evaluation • 6-month warranty • Pan-India service
Disclaimer
Fungilab and all associated product names and model numbers are trademarks of their respective owner(s). Synchronics Electronics Pvt. Ltd. is an independent third-party repair provider and is not affiliated with, authorised by, sponsored by or endorsed by Fungilab. Product names and model numbers are used solely to identify the equipment on which repair services are offered, and no trademark ownership is claimed or implied.
Get Your Equipment
Back in Action — Fast
Send us your faulty industrial electronics. Our engineers will diagnose it and provide a detailed quote within 24 hours — with no obligation to proceed.
Free Evaluation
No obligation
48hr Turnaround
Fastest in India
6-Month Warranty
Every repair
No Fix, No Charge
Zero risk policy
Pan-India Service
Ship from anywhere