HORIBA Repair Services India
HORIBA is a Japan-based global leader in precision measurement, analysis, and environmental monitoring instrumentation. Founded in 1945, HORIBA manufactures advanced diagnostic equipment, emission analysers, particle counters, water quality monitors, and combustion gas analysers used across automotive, environmental, pharmaceutical, and industrial sectors. HORIBA has a significant presence in India through its subsidiaries and distribution networks, supplying critical test and measurement equipment to Indian automotive OEMs, environmental labs, and manufacturing plants.
HORIBA is a Japan-based global leader in precision measurement, analysis, and environmental monitoring instrumentation. Founded in 1945, HORIBA manufactures advanced diagnostic equipment, emission analysers, particle counters, water quality monitors, and combustion gas analysers used across automotive, environmental, pharmaceutical, and industrial sectors. HORIBA has a significant presence in India through its subsidiaries and distribution networks, supplying critical test and measurement equipment to Indian automotive OEMs, environmental labs, and manufacturing plants.
Synchronics Electronics specializes in repairing HORIBA's precision diagnostic and measurement instruments, including combustion analysers, particle measurement systems, and environmental monitoring units. Our 180+ engineers have extensive expertise with HORIBA's sensor-based systems, calibration modules, and electronic control circuits. We understand the critical nature of HORIBA equipment downtime in automotive testing labs and environmental compliance operations. Customers across India trust Synchronics for fast, accurate HORIBA repairs with full component-level diagnosis and factory-equivalent performance restoration.
Expert repair of HORIBA combustion analysers, emission testers, and precision measurement systems across India.
HORIBA Equipment We Repair — By Category
HORIBA Product Lines We Repair
Our engineers are trained on the full HORIBA product range. Below are the major product families we service.
HORIBA Combustion Gas Analysers (Portable & Bench-Top)
Portable and stationary combustion gas analysers for measuring NOx, CO, CO2, O2, and HC emissions. Common issues include sensor drift, faulty lambda probes, display malfunction, and calibration failures after prolonged field use or environmental exposure.
HORIBA Particle Counters and Aerosol Analysers
Optical particle counters and laser-based aerosol analysers for cleanroom monitoring and environmental dust measurement. Typical faults include optical window contamination, detector failure, flow sensor errors, and software communication breakdowns.
HORIBA Water Quality Monitoring Systems
Multi-parameter water analysers measuring pH, dissolved oxygen, turbidity, conductivity, and BOD. Common repair needs involve sensor calibration errors, electrode degradation, temperature compensation failures, and data logging module faults.
HORIBA Emission Test Benches and Automotive Diagnostic Systems
Integrated automotive emission test systems for chassis dynamometer labs and R&D facilities. Failures typically involve sensor integration issues, gas dilution system problems, data acquisition card faults, and real-time controller crashes.
HORIBA Infrared Gas Analysers (NDIR)
Non-dispersive infrared analysers for CO2, CO, CH4, and hydrocarbon detection in automotive and industrial exhaust monitoring. Common faults include infrared lamp degradation, optical path misalignment, detector sensitivity loss, and analogue signal conditioning failures.
HORIBA Control Electronics and Data Loggers
Embedded controllers, display units, and data acquisition modules for HORIBA instruments. Repair challenges include RS-485 communication loss, SD card read failures, touchscreen unresponsiveness, and firmware corruption.
Why Choose Synchronics for HORIBA Repairs?
PCB-Level Expertise
We repair down to the component level — not just swap boards. Our engineers identify root causes, replace failed IGBTs, capacitors, processors, and gate drivers on HORIBA equipment.
Fast Turnaround
Standard 7–10 working days. Express 3–5 days available for critical breakdowns. Emergency same-day/next-day service for unplanned downtime.
6-Month Warranty
Every repaired unit ships with a 6-month comprehensive warranty on parts and labour. Our repair success rate is over 94% across all brands.
All-India Service
Couriered repairs accepted from any city in India. Doorstep pickup available in Vadodara, Mumbai, Pune, Ahmedabad, Surat, Chennai, and more.
Common HORIBA Equipment Faults We Fix
Based on 30+ years of repair data, these are the most frequent failure modes we see in HORIBA equipment arriving at our workshop.
- ✓Lambda probe sensor reading drift or non-response — HORIBA combustion analysers depend on heated oxygen sensors that degrade after high-temperature exposure, moisture ingress, or contamination from fuel residues. Drift causes incorrect air-fuel ratio readings in automotive test labs.
- ✓Particle counter optical window clouding and zero-check failure — HORIBA particle counters operate in dusty manufacturing and cleanroom environments. Optical surfaces collect microscopic deposits, and internal flow paths accumulate powder or liquid residue, causing false particle counts and calibration errors.
- ✓Water quality sensor electrode failure or unstable pH/DO readings — HORIBA water analysers operate in harsh aqueous environments causing electrode coating, ion contamination, and reference electrode depletion. Temperature sensors also fail due to thermistor degradation in process water systems.
- ✓MEXA series display blank, corrupted characters, or touchscreen unresponsive — HORIBA combustion analysers and emission benches experience display failures due to backlight burnout, LCD panel degradation, or touchscreen controller IC solder joint failure from thermal cycling in lab environments.
- ✓Calibration gas flow sensor fault or dilution system inaccuracy — HORIBA emission test benches use precision mass flow controllers and gas dilution regulators. Membrane rupture, flow sensor thermal drift, or regulator diaphragm fatigue cause incorrect gas mixing ratios, invalidating test results.
- ✓Data communication loss between HORIBA analyser and computer or PLC — RS-232, RS-485, or USB communication failures in HORIBA systems result from faulty COM ports, corrupted firmware in control modules, cable degradation, or protocol mismatch after software updates.
How We Repair Your HORIBA Unit
Receive & Log
Your unit is logged into our tracking system with a unique job number. You receive WhatsApp / email updates at every stage.
Fault Diagnosis
Board-level diagnosis using oscilloscopes, LCR meters, and thermal cameras. Root cause identified before any repair begins.
Component Repair
Faulty ICs, capacitors, MOSFETs, IGBTs, and gate drivers replaced with genuine or equivalent-spec components.
Full-Load Test
Unit tested under rated load with original or equivalent motor. All parameters verified. 6-month warranty issued.
Industries Using HORIBA Equipment
We serve plant maintenance teams across all major industries where HORIBA automation is deployed.
Frequently Asked Questions — HORIBA Repairs
Do you repair HORIBA equipment anywhere in India?+
Yes. Synchronics Electronics provides PAN-India HORIBA repair service covering combustion analysers, particle counters, water quality monitors, and emission test systems. We operate from our primary facility in Vadodara, Gujarat, and offer door pickup from major industrial cities including Mumbai, Delhi, Pune, Hyderabad, Chennai, Ahmedabad, and Bangalore. Customers can also courier equipment directly to our facility for fastest repair turnaround.
What is the typical repair time for a HORIBA combustion analyser calibration failure?+
Most HORIBA calibration and sensor drift issues are diagnosed and resolved within 3-5 working days at Synchronics. This includes sensor replacement, full span and zero calibration against HORIBA reference standards, and functional testing. Emergency expedited repairs can be completed in 24-48 hours. We notify you immediately upon receipt and provide daily updates on complex repairs.
Can Synchronics repair HORIBA emission test benches and chassis dynamometer systems?+
Yes. Synchronics has extensive experience with large-scale HORIBA MEXA and OBS emission test benches used in Indian automotive OEM labs and R&D centres. We perform on-site diagnostics for complex systems, repair gas analysers, flow controllers, dilution systems, and data acquisition electronics. We also provide calibration verification and compliance documentation for regulatory testing.
Do you provide HORIBA spare parts, or only repair services?+
Synchronics provides both repair service and genuine HORIBA spare parts including sensors, electrodes, optics, and control modules. We maintain stock of fast-moving HORIBA components and can source rare or discontinued parts through our vendor network. All parts come with HORIBA certification and warranty.
What quality assurance does Synchronics provide on HORIBA repairs?+
All HORIBA repairs include complete component-level testing, factory-equivalent performance verification, and 12-month warranty on parts and labour. We maintain HORIBA calibration reference standards and test equipment to validate sensor accuracy, measurement linearity, and response time post-repair. Customers receive detailed test reports and calibration certificates where applicable.
How do I send my HORIBA unit for repair?+
Pack the unit securely and courier it to our Vadodara workshop. Include a note with the fault description and your contact details. We will log it into our system and WhatsApp you a job number within 24 hours of receipt. Doorstep pickup is available in Vadodara, Ahmedabad, Surat, Mumbai, and Pune.
What is the cost of repairing a HORIBA drive or PLC?+
Repair cost depends on the model and the fault. We offer a free diagnosis — once we identify the fault, we provide a fixed quotation before proceeding. Typical repairs cost 20–40% of the new unit price. We will never repair without your approval.
What warranty do you provide on HORIBA repairs?+
All repaired units carry a 6-month comprehensive warranty covering the same fault and related issues. If the fault recurs within the warranty period, we repair it free of cost.
Do you provide a no-fix, no-fee guarantee?+
Yes. If we cannot repair your HORIBA unit after diagnosis, you pay only the diagnosis fee (₹500–₹1,500 depending on the product). The unit is returned to you at no additional charge.
HORIBA Repair Catalog
Showing 1–2 of 2 HORIBA products

Other Brands We Repair in the Same Categories
Get Your Equipment
Back in Action — Fast
Send us your faulty industrial electronics. Our engineers will diagnose it and provide a detailed quote within 24 hours — with no obligation to proceed.
Free Evaluation
No obligation
48hr Turnaround
Fastest in India
6-Month Warranty
Every repair
No Fix, No Charge
Zero risk policy
Pan-India Pickup
Doorstep service