MTS Repair Services India
MTS Systems Corporation is a global leader in mechanical testing and simulation systems, headquartered in Eden Prairie, Minnesota. MTS equipment is critical for material testing, structural validation, and durability assessment across automotive, aerospace, and manufacturing sectors. Their test frames, actuators, and control systems are deployed in R&D labs, QA facilities, and production environments worldwide, including major Indian automotive and defence manufacturing clusters.
MTS Systems Corporation is a global leader in mechanical testing and simulation systems, headquartered in Eden Prairie, Minnesota. MTS equipment is critical for material testing, structural validation, and durability assessment across automotive, aerospace, and manufacturing sectors. Their test frames, actuators, and control systems are deployed in R&D labs, QA facilities, and production environments worldwide, including major Indian automotive and defence manufacturing clusters.
Synchronics Electronics specializes in repairing MTS test system electronics, control modules, and sensor interfaces used across Indian manufacturing and research institutions. Our 180+ engineers have extensive experience restoring MTS FlexTest control systems, servo-hydraulic actuator drivers, and data acquisition modules. We understand the critical precision requirements of MTS equipment and deliver turnaround repairs that meet original equipment specifications — essential for labs where measurement accuracy directly impacts product certification and compliance.
Expert repair of MTS test system electronics and hydraulic servo controls across India.
MTS Equipment We Repair — By Category
MTS Product Lines We Repair
Our engineers are trained on the full MTS product range. Below are the major product families we service.
MTS FlexTest Control Systems
Modular test control platforms managing servo-hydraulic and electro-mechanical actuators. Common issues include analogue signal conditioning faults, PLC firmware corruption, and real-time data acquisition module failures affecting test repeatability.
MTS Servo-Hydraulic Actuator Drivers
High-precision proportional valve controllers and servo amplifiers for dynamic testing. Typical faults include proportional solenoid coil failures, feedback transducer signal loss, and closed-loop control instability causing erratic actuator response.
MTS Data Acquisition and Sensor Interface Modules
Multifunction I/O modules for strain gauge, LVDT, pressure, and displacement sensing in test frames. Repair focus includes amplifier offset drift, thermocouple signal conditioning faults, and digital encoder interface failures.
MTS Hydraulic Power Supply Electronics
Pressure regulation, pump motor control, and cooler management boards. Common faults involve pump motor contactor failures, pressure relief solenoid coil burnout, and filter blockage indicator circuit malfunctions.
MTS Load Cell and Transducer Conditioning
Signal conditioning amplifiers for load cells, displacement transducers, and custom sensor interfaces.
Why Choose Synchronics for MTS Repairs?
PCB-Level Expertise
We repair down to the component level — not just swap boards. Our engineers identify root causes, replace failed IGBTs, capacitors, processors, and gate drivers on MTS equipment.
Fast Turnaround
Standard 7–10 working days. Express 3–5 days available for critical breakdowns. Emergency same-day/next-day service for unplanned downtime.
6-Month Warranty
Every repaired unit ships with a 6-month comprehensive warranty on parts and labour. Our repair success rate is over 94% across all brands.
All-India Service
Couriered repairs accepted from any city in India — Vadodara, Mumbai, Pune, Ahmedabad, Surat, Chennai, and more.
Common MTS Equipment Faults We Fix
Based on 30+ years of repair data, these are the most frequent failure modes we see in MTS equipment arriving at our workshop.
- ✓FlexTest control system processor crash during data logging — SRAM memory degradation or corrupted test configuration files in the control module EEPROM. Extended thermal cycling in lab environments accelerates memory cell failure, causing unpredictable halts mid-test.
- ✓Servo-hydraulic actuator exhibits erratic position feedback or control instability — LVDT displacement transducer output signal degradation, broken feedback cable shielding, or proportional valve spool centering spring fatigue causing hysteresis in closed-loop control. Common in high-cycle fatigue testing environments.
- ✓Load cell amplifier zero drift or nonlinearity in measurement accuracy — Excitation voltage regulator failing or op-amp input offset voltage creep due to aged capacitors. Thermal stress in production test environments causes component drift, leading to systematic measurement bias and failed test correlation.
- ✓Proportional solenoid coil burnout in servo valve control — Sustained overcurrent from failed current limiting circuit, moisture ingress into coil windings causing breakdown, or mechanical armature stiction preventing coil closure and leading to continuous current draw.
- ✓Data acquisition module multifunction I/O card loses communication with FlexTest controller — Ethernet interface chip failure, corrupted firmware bootloader, or shorted I/O card backplane connector pin causing PCI/PCIe bus lockup. Common after lab bench power surges or improper card ejection.
- ✓Pump motor contactor fails to energize or chatters during pressure control — Contactor coil degradation, burned contact surfaces from switching transients, or failing auxiliary contact block preventing proper pump motor circuit closure. Thermal overload in continuous operation accelerates coil insulation breakdown.
How We Repair Your MTS Unit
Receive & Log
Your unit is logged into our tracking system with a unique job number. You receive WhatsApp / email updates at every stage.
Fault Diagnosis
Board-level diagnosis using oscilloscopes, LCR meters, and thermal cameras. Root cause identified before any repair begins.
Component Repair
Faulty ICs, capacitors, MOSFETs, IGBTs, and gate drivers replaced with genuine or equivalent-spec components.
Full-Load Test
Unit tested under rated load with original or equivalent motor. All parameters verified. 6-month warranty issued.
Industries Using MTS Equipment
We serve plant maintenance teams across all major industries where MTS automation is deployed.
Frequently Asked Questions — MTS Repairs
Is Synchronics an authorised MTS service centre?+
No. Synchronics Electronics Pvt. Ltd. is an independent third-party repair provider. We are not affiliated with, authorised by, sponsored by or endorsed by MTS or its group companies, and we are not an official MTS service centre, dealer or representative. Brand names and model numbers are used only to identify the equipment we repair. If your equipment is under manufacturer warranty or a service contract, please contact the manufacturer first — third-party repair may affect that cover.
Do you repair MTS equipment anywhere in India?+
Yes. We repair the full MTS product range — FlexTest controllers, servo-hydraulic actuator drivers, data acquisition modules, and sensor conditioning electronics. All repairs are completed at our facility in Vadodara, Gujarat, with turnaround times as fast as 7-10 days for standard boards.
What is the typical repair cost for MTS FlexTest controller or servo driver failures?+
Critical boards used in production test labs often justify the repair investment versus replacement. Synchronics also stocks common MTS replacement modules to minimize downtime — contact our service team for urgent repair availability.
How do you ensure MTS test equipment accuracy after repair?+
Synchronics validates all repaired MTS electronics against original equipment performance specifications. For load cell amplifiers and sensor conditioning modules, we verify linearity, zero offset, and excitation voltage stability using certified reference transducers. For FlexTest controllers and servo drivers, we perform dynamic closed-loop control testing on our MTS simulator bench before shipment.
What is your experience with MTS actuator feedback transducer and LVDT failures?+
MTS displacement transducers (LVDTs) are a frequent repair focus in our workshop — typical failures include coil wire fracture, core centering spring fatigue, and signal cable shield corrosion. We have repaired 100+ MTS servo-hydraulic test systems across automotive crash labs, material science institutes, and tyre testing facilities in India. Our engineers understand the precision requirements of MTS fatigue testing and deliver transducer repairs that restore original control system accuracy.
How do I send my MTS unit for repair?+
Pack the unit securely and courier it to our Vadodara workshop. Include a note with the fault description and your contact details. We will log it into our system and WhatsApp you a job number within 24 hours of receipt.
What is the cost of repairing a MTS drive or PLC?+
Repair cost depends on the model and the fault. We offer a free diagnosis — once we identify the fault, we provide a fixed quotation before proceeding. Typical repairs cost 20–40% of the new unit price. We will never repair without your approval.
What warranty do you provide on MTS repairs?+
All repaired units carry a 6-month comprehensive warranty covering the same fault and related issues. If the fault recurs within the warranty period, we repair it free of cost.
Do you provide a no-fix, no-fee guarantee?+
Yes. For standard units, evaluation is free and included in the repair cost — if we cannot repair your MTS unit, no repair charge is raised. A physical inspection charge applies only if the unit has already been subjected to a third-party repair attempt, and we tell you before we start.
MTS Repair Catalog
Showing 1–2 of 2 MTS products

TEMPOSONICS MAGNETOSTRICTIVE LINEAR POSITION SENSOR RPK0450MD601A010010C01
265289
Linear Position Sensors
Other Brands We Repair in the Same Categories
Disclaimer
MTS and all associated product names and model numbers are trademarks of their respective owner(s). Synchronics Electronics Pvt. Ltd. is an independent third-party repair provider and is not affiliated with, authorised by, sponsored by or endorsed by MTS. Product names and model numbers are used solely to identify the equipment on which repair services are offered, and no trademark ownership is claimed or implied.
Get Your Equipment
Back in Action — Fast
Send us your faulty industrial electronics. Our engineers will diagnose it and provide a detailed quote within 24 hours — with no obligation to proceed.
Free Evaluation
No obligation
48hr Turnaround
Fastest in India
6-Month Warranty
Every repair
No Fix, No Charge
Zero risk policy
Pan-India Service
Ship from anywhere
