Skip to main content
OPEN NOW
0s

0% of today's working hours elapsed

Office Hours (IST)

Track Repair →
1 Products

UNIPROBE Repair Services India

UNIPROBE is a leading American manufacturer of advanced process measurement and instrumentation systems used across global manufacturing and energy sectors. Specializing in multi-parameter sensing probes, data acquisition modules, and real-time monitoring hardware, UNIPROBE equipment is critical in power generation, refineries, and process industries worldwide. Their robust sensor technology and industrial-grade electronics have established strong presence in Indian manufacturing facilities, particularly in thermal power plants and petrochemical complexes.

UNIPROBE is a leading American manufacturer of advanced process measurement and instrumentation systems used across global manufacturing and energy sectors. Specializing in multi-parameter sensing probes, data acquisition modules, and real-time monitoring hardware, UNIPROBE equipment is critical in power generation, refineries, and process industries worldwide. Their robust sensor technology and industrial-grade electronics have established strong presence in Indian manufacturing facilities, particularly in thermal power plants and petrochemical complexes.

Synchronics Electronics has built deep expertise repairing UNIPROBE measurement systems and process monitoring hardware across India's manufacturing heartland. We specialize in UNIPROBE probe diagnostics, signal conditioning module repairs, data logger fault resolution, and sensor interface board rebuilds.

1
Products in Catalog
1+
Product Categories
6 Mo
Repair Warranty
32+
Years Experience

UNIPROBE Equipment We Repair — By Category

Repair Expertise

UNIPROBE Product Lines We Repair

Our engineers are trained on the full UNIPROBE product range. Below are the major product families we service.

UNIPROBE Multi-Parameter Sensing Probes

High-temperature and pressure measurement probes used in power generation and refinery applications. Common issues include sensor drift, thermocouple connector corrosion, protection sheath fractures, and signal noise in harsh environments.

UP-MT SeriesUP-HPT High-PressureUP-DTS Dual Thermocouple

UNIPROBE Data Acquisition Modules

Signal conditioning and data logging hardware that interfaces with industrial control systems. Faults include analog-to-digital converter failures, input channel dropout, memory corruption in firmware, and communication protocol errors with RTU/PLC systems.

DAM-4000DAM-6000 MultichannelDAM-8000 Industrial

UNIPROBE Sensor Interface Boards

PCB assemblies that translate probe signals into industrial standard outputs (4-20mA, 0-10V, RS485). Board-level faults include voltage regulator failures, optocoupler burn-out, capacitor dry-out, and digital isolator damage from transient surges.

SIB-100SIB-200 Dual-ChannelSIB-RS485 Industrial Protocol

UNIPROBE Temperature Transmitter Systems

Integrated head-mounted transmitters combining probe, signal processing, and output in single package.

UTT-3000UTT-3500 Remote MountUTT-4000 Advanced

UNIPROBE Wireless Monitoring Gateway

Industrial IoT hardware for remote UNIPROBE probe monitoring and predictive maintenance. Common faults involve antenna connector looseness, Wi-Fi module firmware crashes, cloud authentication timeout, and lithium battery depletion.

WMG-100WMG-200 CellularWMG-300 Dual-Band

UNIPROBE Calibration Reference Standards

Precision equipment for in-situ UNIPROBE probe verification and traceability certification.

CRS-1000CRS-2000 PortableCRS-3000 Laboratory
Why Us

Why Choose Synchronics for UNIPROBE Repairs?

🔬

PCB-Level Expertise

We repair down to the component level — not just swap boards. Our engineers identify root causes, replace failed IGBTs, capacitors, processors, and gate drivers on UNIPROBE equipment.

⚡

Fast Turnaround

Standard 7–10 working days. Express 3–5 days available for critical breakdowns. Emergency same-day/next-day service for unplanned downtime.

🛡️

6-Month Warranty

Every repaired unit ships with a 6-month comprehensive warranty on parts and labour. Our repair success rate is over 94% across all brands.

📦

All-India Service

Couriered repairs accepted from any city in India — Vadodara, Mumbai, Pune, Ahmedabad, Surat, Chennai, and more.

Diagnosis

Common UNIPROBE Equipment Faults We Fix

Based on 30+ years of repair data, these are the most frequent failure modes we see in UNIPROBE equipment arriving at our workshop.

  • ✓UNIPROBE probe thermocouple open circuit fault — Thermocouple wires inside the probe protection sheath break due to vibration, thermal cycling stress, or manufacturing micro-fractures in the junction. This is common in power plant applications where probes experience 20-30 thermal shock cycles daily.
  • ✓UNIPROBE DAM-4000 analog input channel dropout — Input connector pin corrosion or internal PCB via micro-cracking around the analog front-end IC due to moisture ingress in humid Indian industrial environments. Also caused by repeated thermal cycling in tropical refineries.
  • ✓UNIPROBE sensor interface board 4-20mA output stuck at minimum — Voltage regulator IC failure (typically TL431 reference or supporting op-amp) due to input surge from switching motor contactors or VFD harmonic interference common in Indian textile mills and process plants.
  • ✓Also caused by aging of the internal cold-junction compensation circuit capacitors.
  • ✓UNIPROBE WMG-100 wireless gateway Wi-Fi module crash loop — Firmware corruption in ESP8266 Wi-Fi module due to incomplete OTA (over-the-air) update interrupted by power loss. Also triggered by incompatible security certificate in Indian telecom 5G transition environments.
  • ✓UNIPROBE probe protection sheath external crack and moisture ingress — Stainless steel 316L sheath micro-cracks due to stress concentration at probe tip weld seam. Accelerated in high-humidity refinery and coastal power plant environments across Gujarat and Maharashtra where salt-fog corrosion is endemic.
Process

How We Repair Your UNIPROBE Unit

📥
Step 1

Receive & Log

Your unit is logged into our tracking system with a unique job number. You receive WhatsApp / email updates at every stage.

🔬
Step 2

Fault Diagnosis

Board-level diagnosis using oscilloscopes, LCR meters, and thermal cameras. Root cause identified before any repair begins.

🔧
Step 3

Component Repair

Faulty ICs, capacitors, MOSFETs, IGBTs, and gate drivers replaced with genuine or equivalent-spec components.

✅
Step 4

Full-Load Test

Unit tested under rated load with original or equivalent motor. All parameters verified. 6-month warranty issued.

Sectors

Industries Using UNIPROBE Equipment

We serve plant maintenance teams across all major industries where UNIPROBE automation is deployed.

Thermal Power Generation and Coal-Fired Power PlantsOil Refining and Petrochemical ProcessingNatural Gas Processing and LNG TerminalsPharmaceutical Manufacturing and GMP CleanroomsFood and Beverage ProcessingCement and Heavy Minerals ProductionSteel Mills and Metal Casting FoundriesDistrict Heating and HVAC Systems
FAQ

Frequently Asked Questions — UNIPROBE Repairs

Is Synchronics an authorised UNIPROBE service centre?+

No. Synchronics Electronics Pvt. Ltd. is an independent third-party repair provider. We are not affiliated with, authorised by, sponsored by or endorsed by UNIPROBE or its group companies, and we are not an official UNIPROBE service centre, dealer or representative. Brand names and model numbers are used only to identify the equipment we repair. If your equipment is under manufacturer warranty or a service contract, please contact the manufacturer first — third-party repair may affect that cover.

Do you repair UNIPROBE equipment anywhere in India?+

Yes. All repairs are performed in our Vadodara, Gujarat facility. We provide courier return at no extra charge for customers across India.

What is the typical turnaround time for UNIPROBE probe repair at Synchronics?+

Standard repair turnaround is 7-10 working days from receipt of equipment. Urgent repairs with expedited parts sourcing can be completed in 3-5 days at no additional charge. Complex issues requiring sensor element replacement or board-level redesign may take 12-15 days. We maintain stock of common UNIPROBE replacement parts including thermocouple wire, RTD elements, connector pins, and voltage regulator ICs, which accelerates repair completion.

Do UNIPROBE data acquisition modules need firmware updates after repair?+

Yes, Synchronics always updates UNIPROBE DAM-series firmware to the latest stable release during repair. We have access to UNIPROBE firmware repositories and perform compatibility testing with common PLC platforms used across Indian industry (Siemens, Allen Bradley, Mitsubishi). Post-repair testing includes communication protocol verification on Modbus RTU, analog input channel linearity checks, and SD card memory integrity validation. Firmware updates are included at no extra cost.

Can Synchronics repair UNIPROBE equipment damaged by power surges or lightning strikes?+

Yes. UNIPROBE data acquisition and transmitter boards are frequently damaged by transient surges from industrial switching equipment, VFD harmonic distortion, or lightning strikes — common in Indian manufacturing environments. Synchronics performs comprehensive surge damage assessment, identifies all damaged components (voltage regulators, optocouplers, rectifier diodes, microcontroller I/O pins), and performs complete board-level rebuild. We also upgrade surge suppression circuits with additional TVS diodes and ferrite filtering to prevent recurrence.

How do I send my UNIPROBE unit for repair?+

Pack the unit securely and courier it to our Vadodara workshop. Include a note with the fault description and your contact details. We will log it into our system and WhatsApp you a job number within 24 hours of receipt.

What is the cost of repairing a UNIPROBE drive or PLC?+

Repair cost depends on the model and the fault. We offer a free diagnosis — once we identify the fault, we provide a fixed quotation before proceeding. Typical repairs cost 20–40% of the new unit price. We will never repair without your approval.

What warranty do you provide on UNIPROBE repairs?+

All repaired units carry a 6-month comprehensive warranty covering the same fault and related issues. If the fault recurs within the warranty period, we repair it free of cost.

Do you provide a no-fix, no-fee guarantee?+

Yes. For standard units, evaluation is free and included in the repair cost — if we cannot repair your UNIPROBE unit, no repair charge is raised. A physical inspection charge applies only if the unit has already been subjected to a third-party repair attempt, and we tell you before we start.

UNIPROBE Repair Catalog

Showing 1–1 of 1 UNIPROBE products

32+
Years in Business
80,000+
Units Repaired
150+
Workstations
4.8★
682 Reviews

Disclaimer

UNIPROBE and all associated product names and model numbers are trademarks of their respective owner(s). Synchronics Electronics Pvt. Ltd. is an independent third-party repair provider and is not affiliated with, authorised by, sponsored by or endorsed by UNIPROBE. Product names and model numbers are used solely to identify the equipment on which repair services are offered, and no trademark ownership is claimed or implied.

Trusted Since 1994 · ISO Certified · 32+ Years

Get Your Equipment
Back in Action — Fast

Send us your faulty industrial electronics. Our engineers will diagnose it and provide a detailed quote within 24 hours — with no obligation to proceed.

✓

Free Evaluation

No obligation

⚡

48hr Turnaround

Fastest in India

🛡

6-Month Warranty

Every repair

₹

No Fix, No Charge

Zero risk policy

📦

Pan-India Service

Ship from anywhere